M204.2607

From m204wiki
Revision as of 17:36, 13 March 2018 by DmeWiccan (talk | contribs) (Automatically generated page update)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.2607  CPQZACTN and CPQZSECS are corequisite parameters

System manager response: The CCAIN User 0 parameters CPQZSECS and CPQZACTN must both be specified if either is specified.

You will also get this message if both parameters are specified, but CPQZACTN is zero (0) and both RCVOPT bit X'01' is on and the NUSERS parameter is greater than one (1). Make appropriate changes to the parameters, and resubmit the job.

CPQZSECS determines how many seconds to wait after the checkpoint extended quiesce period has started before taking the CPQZACTN action. If the CHECKPOINT END EXTENDED QUIESCE command is not entered within this time period, then the action specified by the CPQZACTN parameter setting is taken.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter

Back to list of messages