M204.2901
M204.2901 **Fix is available for problem** FOPT=x'10' (dts) is not supported during FLOD/FILELOAD
Neither FLOD nor FILELOAD support the date/time stamp (DTS) feature. All previous DTS values will be restored, but date/time stamps from the actual FLOD or FILELOAD will not be stored.
File manager response: Remove the DTSFN parameter from the CCAIN stream, or reset FOPT to turn off the X'10' bit, and rerun the job.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=8 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |