M204.2901  **Fix is available for problem** FOPT​=​x'10' (dts) is not supported during FLOD​/​FILELOAD

Neither FLOD nor FILELOAD support the date/time stamp (DTS) feature. All previous DTS values will be restored, but date/time stamps from the actual FLOD or FILELOAD will not be stored.

File manager response: Remove the DTSFN parameter from the CCAIN stream, or reset FOPT to turn off the X'10' bit, and rerun the job.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=8Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter