M204.2012  token server token2 error token3

A PQO or Remote SQL request failed for the above reason. The type of error, if noted, may be "COMMUNICATION" or "PROTOCOL" (for example, a configuration mismatch between the PQO server and client caused the two to get out of sync).

Response: Retry the request. Alert the system manager in case of repeated failure.

System manager response: If a communication error, refer to the accompanying messages M204.2010 and M204.2011. If a protocol error or other type, examine the release level and the required system definitions for both server and client.


Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter