M204.2294
M204.2294 TCP/IP interface 'token' has already been created
An OPEN LINK command for a TCP/IP link failed, because an interface with the same name has already been opened in this address space.
System manager response: If this was an oversight, ignore the message — the interface is ready to be used. On the other hand, if your intention was to change the operating characteristics of the link, you must first close the link before attempting to reopen it.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |