M204.2066  Multi-tasking requires KOMMOPT​=​1​,​ NMPSUBS set to 0

User 0 input specified NMPSUBS=0, which enables MP/204, however KOMMOPT was not set to 1. Since the multiple KOMMs feature is required by MP/204, MP is disabled for the run by setting NMPSUBS=0.

System manager response: Set KOMMOPT=1 in order to use MP/204.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITADWrites the message with line type AD to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
OPRWrites the message to the (operator) console