M204.1987

From m204wiki
Revision as of 23:57, 16 March 2018 by ELowell (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.1987  Remote file fileName may not be accessed with multiple process groups

The same remote file at the same remote location may not be accessed through more than one PROCESSGROUP. This illegal access has been attempted.

Response: Contact the system manager.

System manager response: This error will be received if the same value of the LOCATION parameter is used for more than one Online. Ensure that each Model 204 Online participating in the PQO configuration has a unique value for the LOCATION parameter. If the error persists, the network definitions on the client node must be in error. Review the LINK, PROCESSGROUP, and PROCESS definitions for PQO.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter

Back to list of messages