M204.1435
M204.1435 Error during regenerate, REGENERATE is cancelled, RF entry number token
During regeneration, an open failure for the CCAGEN data set occurred, or I/O errors or sequence errors were encountered while processing journal entries. Model 204 will take a snap dump and end the run.
The RF (Roll Forward) entry number token is the sequence number of the journal entry that was being processed at the time of the error.
System manager response: This message follows more specific messages related to the open failure, or I/O or sequence errors. Refer to your CCAAUDIT output or console log, correct the error, and rerun media recovery. If the problem remains, contact Technical Support and have the following documentation available:
- Audit trail
- Snap dumps
- UTILJ output for CCAGEN data set
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |