M204.2457

From m204wiki
Revision as of 19:00, 5 June 2018 by JAL (talk | contribs) (uppercase for "TIME")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.2457  TIME ​>​ 18325 specified - TIMESTOP will be ignored

A TIME parameter was specified for the job that exceeded the Model 204 internal limit of 18325 (12.7 days). No internal time limit is used. The external limit remains unchanged. When the external limit is reached, the job is canceled. Model 204 ignores the TIMESTOP parameter, and it does not gracefully shut down before the cancel.

System manager response: To respect TIMESTOP, always set TIME < 18325. If you want unlimited time, set TIMESTOP to 0 and TIME to 1440. If the TIME parameter is not specified on either the job or execute card, the default is provided by JES.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter

Back to list of messages