AUDITOPT parameter

From m204wiki
Revision as of 05:19, 1 March 2024 by RPuszewski (talk | contribs) (→‎Description)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Audit options

Summary

Default value
X'00000000'
Parameter type
System
Where set
On User 0's parameter line or reset by system manager
Related products
All
Introduced
Model 204 V5.1

Description

The AUDITOPT parameter indicates special handling for the auditing of various messages. The parameter contains bit settings with the following possible values:

Setting

Meaning

X'00000000'

Default value

X'00000001'

Authorizes the MSGCTLU command to issue NOAUDIT option.

X'40000000'

Indicates that MQ/204 messages M204.2504, 2505, and 2506 are not to be written to the audit trail if an MQ/204 operation (other than MQGET, MQPUT, or MQPUT1 statement) is successful.

X'80000000'