M204.0027
M204.0027 Aux procedure dictionary full
This error can occur:
- During Model 204 initialization, if unsupported procs have been stored in CCASYS. Only Rocket supplied procs can be stored in CCASYS.
- When the START SUBSYS subsysName command is issued for a subsystem. During a subsystem initialization, the subsystem procedure file is scanned twice. The first scan retrieves the number of subsystem procedures in order to allocate the subsystem's in-core procedure dictionary. The second scan retrieves the procedure information that is copied into the in-core procedure dictionary. If another user adds a new subsystem procedure between the first procedure file scan and the second, the error can occur.
or
Response:
- Remove all non-ROCKET procs from CCASYS and restart Model 204.
- Reissue the START SUBSYS subsysName command. If this doesn't help, issue the DEBUG SUBSYS subsysName command; the messages produced may provide information pointing to the problem.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |