MSIR.0833 Can't set Model 6 -- (reason)

From m204wiki
Revision as of 16:04, 5 April 2013 by JALWiccan (talk | contribs) (Automatically generated page update)
Jump to navigation Jump to search

A RESET MODEL 6 command could not be executed for the indicated reason. The most likely reasons for this error are an insufficiently large LOUTPB which can be corrected by increasing LOUTPB or setting a smaller screen size on the 3270 emulator that received this error. Another likely cause of this error is use of an "old" 3270 emulator that does not support the Write Structured Field Query operation required to support the MODEL 6 capability. For such emulators, the correct model must be set "manually". A wide variety of less common errors are also possible. If the reason indicated for such an error is not clear, contact Technical Support.