POLLNO parameter
Jump to navigation
Jump to search
Relative polling number
Summary
- Default value
- 0
- Parameter type
- User
- Where set
- On user's parameter line
- Related products
- All
- Introduced
- Model 204 V2.1 or earlier
Description
The relative position within a group of terminals
POLLNO must be set to 1 on a group's first parameter line, the line containing the NOTERM parameter. POLLNO must be incremented by 1 for each successive parameter line in a group.
POLLNO applies to the following device types:
| IODEV | Access method/device type |
|---|---|
| 11 | Remote User Language thread (full screen) |
| 17 | IUCV SQL (z/VM) |
| 19 | VTAM or TCPIP (Horizon for Connect*) |
| 29 | Remote User Language thread (line-at-a-time) |
| 39 | IUCV User Language thread (line-at-a-time) |
| 41 | IUCV User Language thread (full screen) |
| 43 | IUCV Host Language Interface thread |