B24SHRWT parameter: Difference between revisions

From m204wiki
Jump to navigation Jump to search
m (ELowell moved page B24SHRWT to B24SHRWT parameter)
No edit summary
Line 1: Line 1:
BATCH204 wait time increment, in milliseconds, between M204.0582 msgs.
{{Template:xxx parameter subtitle}}
==Summary==
==Summary==
<dl>
<dl>

Revision as of 20:12, 8 October 2013

Template:Xxx parameter subtitle

Summary

Default value
300000
Parameter type
System
Where set
On User 0's parameter line by system manager
Related products
All
Introduced
Model 204 V7.1

Description

The BATCH204 wait time increment, in milliseconds, between these messages:

M204.0582: ACCESS TO FILE dataset name PREVENTED BY: jobname

A shared DASD enqueuing conflict occurred for the specified file. Another Model 204 run processing on the same or a different CPU has established an enqueue against this file. This conflicts with the enqueue level you are attempting to establish. Model 204 waits for the file to become available, and if not available after B24SHRWT milliseconds, reissues the message and again waits for the file to become available.