M204.2591

From m204wiki
Revision as of 20:06, 20 March 2018 by JAL (talk | contribs) (add link)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

M204.2591  SESD for socket token link token2 unexpectedly deallocated after socket data was read

The Horizon for TCP/IP interface read data for a socket connection, but the Horizon session manager does not recognize this socket connection as extant. This may be the result of an application error, a temporary increase in system load, or an internal error in the Horizon for TCP/IP interface or in TCP/IP itself.

Response: Contact your system manager.

System manager response: Contact Technical Support for further instructions.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITADWrites the message with line type AD to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter

Back to list of messages