M204.2917 Server dataset token is allocated above 64k cyl. Servers above 64k cyl are not supported.
An attempt has been made to open a server data set allocated on an EAV volume above the 64K-cylinder boundary.
System manager response: Allocate a server data set below the 64K-cylinder boundary, or use servers in storage.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |