Long update unit durations (ms)

Summary

Default value
0
Parameter type
System
Where set
On User 0's parameter line; not resettable
Related products
All
Introduced
Model 204 V3.2.0 or earlier

Description

The number of milliseconds beyond which a user's update unit is counted as a long update unit

The number of long update units and the total duration in milliseconds of all long update units are kept per user for user, since-last, and system statistics. Long update units are not tracked per file.

The update unit is considered to have started at the time of update of the first, local, non-HLI file, and to end at commit or backout.

Both backoutable update units and non-backoutable update units can become long update units.