CPQZSECS parameter: Difference between revisions

From m204wiki
Jump to navigation Jump to search
(Automatically generated page update)
m (misc formatting)
 
(5 intermediate revisions by 3 users not shown)
Line 3: Line 3:
<dl>
<dl>
<dt>Default value
<dt>Default value
<dd>999,999, unless CPQZACTN is explicitly set.
<dd>999,999, unless <var>[[CPQZACTN_parameter|CPQZACTN]]</var> is explicitly set.
<dt>Parameter type
<dt>Parameter type
<dd>System
<dd>System
Line 11: Line 11:
<dd>All
<dd>All
<dt>Introduced
<dt>Introduced
<dd><var class="product">Model 204 V6.1</var> or earlier
<dd><var class="product">Model 204 V5.1</var>  
</dl>
</dl>
==Description==
==Description==
<p>The CPQZSECS parameter establishes an extended quiesce timer. An extended quiesce begins after a successful checkpoint taken by a system following a CHECKPOINT SET EXTENDED QUIESCE command; it typically ends with a CHECKPOINT END EXTENDED QUIESCE command.</p>
<p>
<p>The CPQZSECS timer starts at the beginning of the extended quiesce. When the timer expires, the extended quiesce system takes the action specified in CPQZACTN.</p>
The <var>CPQZSECS</var> parameter establishes an extended quiesce timer. An extended quiesce begins after a successful checkpoint taken by a system following a <var>[[CHECKPOINT_command|CHECKPOINT]]</var> <code>SET EXTENDED QUIESCE</code> command; it typically ends with a <code>CHECKPOINT END EXTENDED QUIESCE</code> command.</p>
<p>The CPQZSECS parameter can be set to values 5 to 99999.</p>
<p>
The <var>CPQZSECS</var> timer starts at the beginning of the extended quiesce. When the timer expires, the extended quiesce system takes the action specified in <var>CPQZACTN</var>.</p>
<p>
The <var>CPQZSECS</var> parameter can be set to values 5 to 99999.</p>
 
==Usage==
The <var>CPQZSECS</var> parameter is dependent on the <var>CPQZACTN</var> parameter, meaning: if you
explicitly set one, you must explicitly set the other. Otherwise, the following message is issued:
<p class="code">M204.2607: CPQZACTN AND CPQZXECS ARE COREQUISITE PARAMETERS</p>
<p>
If neither <var>CPQZSECS</var> nor <var>CPQZACTN</var> is specified, <var>CPQZSECS</var> defaults to the value of 999999, meaning that the QZSECS timer expires in just under 33 hours.</p>
<p>
Unlike most other parameters, the value of <var>CPQZSECS</var> is partially validated at Online
initialization and partially validated when a CHKPOINT data set is first opened. </p>
<ul>
<li>If <var>NUSERS</var> is set to one, or <var>RCVOPT</var> bit X'01' is off, which means checkpointing is not active, the extended quiesce CCAIN parameters are not validated. They cannot be reset, and they are viewed as zero.</li>
 
<li>If neither extended quiesce parameter, <var>CPQZSECS</var> or <var>CPQZACTN</var>, is specified on CCAIN,
and <var>NUSERS</var> is greater than one, and checkpointing is active, the <var>CPQZSECS</var> parameter is set to 99999 at the end of system initialization.</li>
 
<li>If <var>NUSERS</var> is greater than one and checkpointing is active, the <var>CPQZSECS</var> parameter can be reset at any time during the run.
<ul>
<li>When the system is not in extended quiesce, the reset takes effect immediately.</li>
 
<li>During extended quiesce, the new value of <var>CPQZSECS</var> takes effect only after the [[M204.2610]] message is issued. (The M204.2610 message is issued every minute.)</li>
 
<li>If the extended quiesce ends before the next M204.2610 message is issued, the new value of <var>CPQZSECS</var> is in effect at the next checkpoint.</li>
</ul></li>
</ul>
 
[[Category:System parameters]]
[[Category:System parameters]]
[[Category:Parameters]]
[[Category:Parameters]]

Latest revision as of 19:31, 8 November 2017

Number of seconds before CPQZACTN

Summary

Default value
999,999, unless CPQZACTN is explicitly set.
Parameter type
System
Where set
On User 0's parameter line or reset by system manager
Related products
All
Introduced
Model 204 V5.1

Description

The CPQZSECS parameter establishes an extended quiesce timer. An extended quiesce begins after a successful checkpoint taken by a system following a CHECKPOINT SET EXTENDED QUIESCE command; it typically ends with a CHECKPOINT END EXTENDED QUIESCE command.

The CPQZSECS timer starts at the beginning of the extended quiesce. When the timer expires, the extended quiesce system takes the action specified in CPQZACTN.

The CPQZSECS parameter can be set to values 5 to 99999.

Usage

The CPQZSECS parameter is dependent on the CPQZACTN parameter, meaning: if you explicitly set one, you must explicitly set the other. Otherwise, the following message is issued:

M204.2607: CPQZACTN AND CPQZXECS ARE COREQUISITE PARAMETERS

If neither CPQZSECS nor CPQZACTN is specified, CPQZSECS defaults to the value of 999999, meaning that the QZSECS timer expires in just under 33 hours.

Unlike most other parameters, the value of CPQZSECS is partially validated at Online initialization and partially validated when a CHKPOINT data set is first opened.

  • If NUSERS is set to one, or RCVOPT bit X'01' is off, which means checkpointing is not active, the extended quiesce CCAIN parameters are not validated. They cannot be reset, and they are viewed as zero.
  • If neither extended quiesce parameter, CPQZSECS or CPQZACTN, is specified on CCAIN, and NUSERS is greater than one, and checkpointing is active, the CPQZSECS parameter is set to 99999 at the end of system initialization.
  • If NUSERS is greater than one and checkpointing is active, the CPQZSECS parameter can be reset at any time during the run.
    • When the system is not in extended quiesce, the reset takes effect immediately.
    • During extended quiesce, the new value of CPQZSECS takes effect only after the M204.2610 message is issued. (The M204.2610 message is issued every minute.)
    • If the extended quiesce ends before the next M204.2610 message is issued, the new value of CPQZSECS is in effect at the next checkpoint.