M204.1519: Difference between revisions

From m204wiki
Jump to navigation Jump to search
(Automatically generated page update)
(No difference)

Revision as of 15:31, 7 March 2018

M204.1519  Invalid token call from interprocess IODEV

An interprocess IODEV (27) attempted the named action. This action is invalid because the IODEV has no terminal associated with it.

Response: Do not attempt to read or write terminal data from a procedure running on an IODEV=27 thread. Procedure code that executes on an IODEV=27 thread must not attempt to issue terminal I/O statements, such as READ SCREEN.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter
NOTERMDoes not display the message on the user's terminal
SAVESaves the message in the VIEW ERRORS table

Back to list of messages