M204.1519
Jump to navigation
Jump to search
M204.1519 Invalid token call from interprocess IODEV
An interprocess IODEV (27) attempted the named action. This action is invalid because the IODEV has no terminal associated with it.
Response: Do not attempt to read or write terminal data from a procedure running on an IODEV 27 thread. Procedure code that executes on an IODEV 27 thread must not attempt to issue terminal I/O statements, such as Read Screen.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |
SAVE | Saves the message in the VIEW ERRORS table |