M204.2932: Difference between revisions
Jump to navigation
Jump to search
(Automatically generated page update) |
(No difference)
|
Revision as of 18:10, 13 March 2018
M204.2932 Increase SERVNSSZ to at least token for required non swappable server areas
A size request for a table that is kept in the non-swappable server area cannot be satisfied because there is not enough above-the-bar storage space as set by the SERVNSSZ parameter. M204.2932 is issued when the problem is detected after initilization is complete.
This error could occur when a UTABLE command is issued. The command is rejected and the table size is left unchanged.
User response: Decrease the amount of increase in the UTABLE command.
System manager response: If required, increase the non-swappable server area size (SERVNSSZ).
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |