M204.2547: Difference between revisions
Jump to navigation
Jump to search
(Automatically generated page update) |
m (add <code>s) |
||
Line 1: | Line 1: | ||
{{Template:M204.2547 skeleton}} | {{Template:M204.2547 skeleton}} | ||
<P>An <var>[[ENQCTL command|ENQCTL]]</var> command specified a jobname of either EXCL or SHR. This is valid, so processing continues, but it is almost certainly not what was intended. You probably copied the output from a prior ENQCTL display and used it | <P> | ||
as the argument for this command but forgot to remove the EXCL or SHR status from the string.</P> | An <var>[[ENQCTL command|ENQCTL]]</var> command specified a jobname of either <code>EXCL</code> or <code>SHR</code>. This is valid, so processing continues, but it is almost certainly not what was intended. You probably copied the output from a prior <var>ENQCTL</var> display and used it | ||
<p><b>System manager response:</b> Check the arguments on the ENQCTL command that you just entered. If appropriate, reissue the command with the correct arguments.</p> | as the argument for this command but forgot to remove the <code>EXCL</code> or <code>SHR</code> status from the string.</P> | ||
<p> | |||
<b>System manager response:</b> Check the arguments on the <var>ENQCTL</var> command that you just entered. If appropriate, reissue the command with the correct arguments. | |||
</p> | |||
{{Template:M204.2547 footer}} | {{Template:M204.2547 footer}} | ||
<!-- skeleton as it was in pdf/ENQCTL PROCEEDING WITH JOBNAME=jobname/--> | <!-- skeleton as it was in pdf/ENQCTL PROCEEDING WITH JOBNAME=jobname/--> |
Latest revision as of 22:35, 19 March 2018
M204.2547 ENQCTL proceeding with jobname=token
An ENQCTL command specified a jobname of either EXCL
or SHR
. This is valid, so processing continues, but it is almost certainly not what was intended. You probably copied the output from a prior ENQCTL display and used it
as the argument for this command but forgot to remove the EXCL
or SHR
status from the string.
System manager response: Check the arguments on the ENQCTL command that you just entered. If appropriate, reissue the command with the correct arguments.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=0 | Sets batch (single user) return code |
CLASS=I | Information class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |