M204.2547
		
		
		
		Jump to navigation
		Jump to search
		
M204.2547 ENQCTL proceeding with jobname=token
An ENQCTL command specified a jobname of either EXCL or SHR. This is valid, so processing continues, but it is almost certainly not what was intended. You probably copied the output from a prior ENQCTL display and used it
as the argument for this command but forgot to remove the EXCL or SHR status from the string.
System manager response: Check the arguments on the ENQCTL command that you just entered. If appropriate, reissue the command with the correct arguments.
Message attributes:
| RETCODEO=0 | Sets online return code | 
|---|---|
| RETCODEB=0 | Sets batch (single user) return code | 
| CLASS=I | Information class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter | 
| AUDITMS | Writes the message with line type MS to the audit trail | 
| NOCOUNT | Does not increment the error count (ERCNT) parameter |