UDDRFM parameter: Difference between revisions
Jump to navigation
Jump to search
m (typo) |
m (link repair) |
||
Line 16: | Line 16: | ||
==Description== | ==Description== | ||
<p> | <p> | ||
The record format of a data set sent to a device specified by a <var>[[USE command|USE]]</var> command (directed output)</p> | The record format of a data set sent to a device specified by a <var>[[USE command: Directing output|USE]]</var> command (directed output)</p> | ||
<p> | <p> | ||
The setting of <var>UDDRFM</var> can be overridden by the following: </p> | The setting of <var>UDDRFM</var> can be overridden by the following: </p> |
Latest revision as of 18:01, 24 April 2018
USE DDNAME - record format
Summary
- Default value
- X'12' (VA)
- Parameter type
- User
- Where set
- By any user
- Related products
- All
- Introduced
- Model 204 V2.1 or earlier
Description
The record format of a data set sent to a device specified by a USE command (directed output)
The setting of UDDRFM can be overridden by the following:
- Under z/OS, the
RECFM
option of the DD statement for the USE data set - The
RECFM
option of the DEFINE DATASET, DEFINE PRINTER, or DEFINE PUNCH command - Under z/VM, the
RECFM
option of the FILEDEF statement
Valid settings of UDDRFM are:
Setting | Meaning |
---|---|
X'10' | ASA control characters required. |
X'08' | Short lines need padding (for unblocked magnetic tape output). |
X'04' | Undefined records. |
X'02' | Variable-length records. |
X'01' | Fixed-length records. |