M204.0331: Difference between revisions

From m204wiki
Jump to navigation Jump to search
(Automatically generated page update)
 
No edit summary
 
Line 1: Line 1:
{{Template:M204.0331 skeleton}}
{{Template:M204.0331 skeleton}}
<P>
<P>
The IODEV parameter statements for the CICS, TSO, INTERCOMM, and CMS interfaces require the setting of the POLLNO parameter. These are the IODEV statements 29, 11, 41, and 39, respectively. The first statement of each group must have the POLLNO value set to 1 and each statement must follow in ascending sequence. Model&nbsp;204 encountered one of these IODEV groups during initialization and POLLNO was either not set or was not set to 1. </P>
The IODEV parameter statements for the CICS, TSO, INTERCOMM, and CMS interfaces require the setting of the <var>[[POLLNO parameter|POLLNO]]</var> parameter. These are the IODEV statements 29, 11, 41, and 39, respectively. The first statement of each group must have the POLLNO value set to 1 and each statement must follow in ascending sequence. Model&nbsp;204 encountered one of these IODEV groups during initialization and POLLNO was either not set or was not set to 1. </P>
<p>
<p>
<b>System manager response:</b> Verify that the values of POLLNO are correctly set on the user parameter lines. Correct the value and rerun the job. </p>
<b>System manager response:</b> Verify that the values of POLLNO are correctly set on the user parameter lines. Correct the value and rerun the job. </p>
{{Template:M204.0331 footer}}
{{Template:M204.0331 footer}}
<!-- skeleton as it was in pdf/POLLNO MUST START AT 1 AND ASCEND /-->
<!-- skeleton as it was in pdf/POLLNO MUST START AT 1 AND ASCEND /-->

Latest revision as of 22:37, 22 February 2018

M204.0331  POLLNO must start at 1 and ascend

The IODEV parameter statements for the CICS, TSO, INTERCOMM, and CMS interfaces require the setting of the POLLNO parameter. These are the IODEV statements 29, 11, 41, and 39, respectively. The first statement of each group must have the POLLNO value set to 1 and each statement must follow in ascending sequence. Model 204 encountered one of these IODEV groups during initialization and POLLNO was either not set or was not set to 1.

System manager response: Verify that the values of POLLNO are correctly set on the user parameter lines. Correct the value and rerun the job.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter
NOTERMDoes not display the message on the user's terminal