M204.0331
Jump to navigation
Jump to search
M204.0331 POLLNO must start at 1 and ascend
The IODEV parameter statements for the CICS, TSO, INTERCOMM, and CMS interfaces require the setting of the POLLNO parameter. These are the IODEV statements 29, 11, 41, and 39, respectively. The first statement of each group must have the POLLNO value set to 1 and each statement must follow in ascending sequence. Model 204 encountered one of these IODEV groups during initialization and POLLNO was either not set or was not set to 1.
System manager response: Verify that the values of POLLNO are correctly set on the user parameter lines. Correct the value and rerun the job.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |