M204.2255: Difference between revisions
Jump to navigation
Jump to search
(Automatically generated page update) |
m (add link) |
||
Line 2: | Line 2: | ||
<P> | <P> | ||
The <var class="term">fieldname=value</var> constant specified in a LoaD Constant ([[File Load utility: FLOD and FILELOAD commands#Load-constant (LDC) statement|LDC]]) Fastload statement is in violation of <var>BINARY</var> data type validation. The file to be loaded by the <var>FLOD</var> job has | The <var class="term">fieldname=value</var> constant specified in a LoaD Constant ([[File Load utility: FLOD and FILELOAD commands#Load-constant (LDC) statement|LDC]]) Fastload statement is in violation of <var>BINARY</var> data type validation. The file to be loaded by the <var>FLOD</var> job has [[Field attributes#File model feature|Numeric Validation]] specified in the <var>[[FILEMODL parameter|FILEMODL]]</var> parameter; the specific field to be loaded is <var>BINARY</var>. </P> | ||
<P> | <P> | ||
This error message occurs during <var>FLOD</var> compilation, and it prevents Fastload from loading any data to the file. </P> | This error message occurs during <var>FLOD</var> compilation, and it prevents Fastload from loading any data to the file. </P> | ||
<p> | <p> | ||
<b>Response:</b> Correct the LDC instruction by supplying a valid <var>BINARY</var> constant. Re-run the <var>FLOD</var> job. </p> | <b>Response:</b> Correct the LDC instruction by supplying a valid <var>BINARY</var> constant. Re-run the <var>FLOD</var> job. | ||
</p> | |||
{{Template:M204.2255 footer}} | {{Template:M204.2255 footer}} | ||
<!-- skeleton as it was in pdf/VALUE SPECIFIED IN LDC VIOLATES BINARY DATA TYPE VALIDATION, FIELD IGNORED: fieldname = value /--> | <!-- skeleton as it was in pdf/VALUE SPECIFIED IN LDC VIOLATES BINARY DATA TYPE VALIDATION, FIELD IGNORED: fieldname = value /--> |
Latest revision as of 19:53, 16 March 2018
M204.2255 Value specified in LDC violates BINARY data type validation, field ignored: token = token2
The fieldname=value constant specified in a LoaD Constant (LDC) Fastload statement is in violation of BINARY data type validation. The file to be loaded by the FLOD job has Numeric Validation specified in the FILEMODL parameter; the specific field to be loaded is BINARY.
This error message occurs during FLOD compilation, and it prevents Fastload from loading any data to the file.
Response: Correct the LDC instruction by supplying a valid BINARY constant. Re-run the FLOD job.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |