<P>This error can be caused by any of the following: </P><ul>
<P>
<li>Open failed for the CCAGRP data set. </li>
This error can be caused by any of the following: </P>
<ul>
<li>Open failed for the [[Storing and using file group definitions (CCAGRP)|CCAGRP]] data set. </li>
 
<li>Model 204 did not have sufficient DCBs available. </li>
<li>Model 204 did not have sufficient DCBs available. </li>
<li>Model 204 had insufficient SPCORE to create a control block. </li>
 
<li>Model 204 had insufficient <var>SPCORE</var> to create a control block. </li>
 
<li>The CCAGRP data set resides on a read-only device. </li>
<li>The CCAGRP data set resides on a read-only device. </li>
</ul>
</ul>
<p><b>System manager response:</b> Verify each of the above conditions, make the necessary changes, and rerun the job. </p>
<p>
<b>System manager response:</b> Verify each of the above conditions, make the necessary changes, and rerun the job.  
</p>
{{Template:M204.0842 footer}}
{{Template:M204.0842 footer}}
<!-- skeleton as it was in pdf/CREATEG COMMAND REJECTED /-->
<!-- skeleton as it was in pdf/CREATEG COMMAND REJECTED /-->

Latest revision as of 20:13, 15 March 2018

M204.0842  CREATEG command rejected

This error can be caused by any of the following:

  • Open failed for the CCAGRP data set.
  • Model 204 did not have sufficient DCBs available.
  • Model 204 had insufficient SPCORE to create a control block.
  • The CCAGRP data set resides on a read-only device.

System manager response: Verify each of the above conditions, make the necessary changes, and rerun the job.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter