M204.0842  CREATEG command rejected

This error can be caused by any of the following:

  • Open failed for the CCAGRP data set.
  • Model 204 did not have sufficient DCBs available.
  • Model 204 had insufficient SPCORE to create a control block.
  • The CCAGRP data set resides on a read-only device.

System manager response: Verify each of the above conditions, make the necessary changes, and rerun the job.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter