DTS parameter: Difference between revisions
m (→Description: add link) |
|||
Line 16: | Line 16: | ||
==Description== | ==Description== | ||
<p> | <p> | ||
Enables [[Adding a date-time stamp field#Overview of the date-time stamp feature|date/time stamp processing]] when set to 1. | Enables [[Adding a date-time stamp field#Overview of the date-time stamp feature|date/time stamp processing]] when set to 1. As a system manager, you can reset <var>DTS</var> to zero to disable automatic date/time stamps. When DTS is zero, you can update a DTSFN field with values of your choosing.</p> | ||
<table> | <table> | ||
Line 30: | Line 30: | ||
</table> | </table> | ||
< | <ul> | ||
<li>You must be a system manager to reset the <var>DTS</var> parameter. You can reset <var>DTS</var> for your thread only. | |||
<li>When <var>DTS</var> is reset to 0, any open files with the <var>[[FOPT_parameter|FOPT]]</var> parameter X'10' bit on must have been opened with file manager privileges. | |||
<li>If the value of the <var>DTS</var> parameter is 0 on a thread, subsequent opens of <var>FOPT</var> X'10' files must obtain file manager privileges. | |||
</ul> | |||
<p class="note"><b>Note:</b> During <var>[[FLOD command|FLOD]]</var>/<var>[[FILELOAD command|FILELOAD]]</var>, the DTS field, if one is defined to the file, is not updated. This means that a new DTS field defined as part of a file reorganization will not have a value calculated during the reorganization. Existing DTS fields are only added from TAPEI input, and they are not automatically updated by the DTS feature.</p> | <p class="note"><b>Note:</b> During <var>[[FLOD command|FLOD]]</var>/<var>[[FILELOAD command|FILELOAD]]</var>, the DTS field, if one is defined to the file, is not updated. This means that a new DTS field defined as part of a file reorganization will not have a value calculated during the reorganization. Existing DTS fields are only added from TAPEI input, and they are not automatically updated by the DTS feature.</p> |
Revision as of 20:02, 1 August 2017
Date time stamp updates (1=automatic, 0=bypassed)
Summary
- Default value
- 1
- Parameter type
- User
- Where set
- Reset by system manager
- Related products
- All
- Introduced
- Model 204 V7.1
Description
Enables date/time stamp processing when set to 1. As a system manager, you can reset DTS to zero to disable automatic date/time stamps. When DTS is zero, you can update a DTSFN field with values of your choosing.
Value | Behavior |
---|---|
1 | For date/time stamp files, transactions participate in DTS updating. The date/time stamp field of an updated record is automatically updated at the beginning of COMMIT processing.
This is the default setting for the parameter. |
0 | Transactions do not participate in DTS updating. When a transaction does not participate in DTS processing, the date/time stamp field will not be updated on records that are themselves updated. |
- You must be a system manager to reset the DTS parameter. You can reset DTS for your thread only.
- When DTS is reset to 0, any open files with the FOPT parameter X'10' bit on must have been opened with file manager privileges.
- If the value of the DTS parameter is 0 on a thread, subsequent opens of FOPT X'10' files must obtain file manager privileges.
Note: During FLOD/FILELOAD, the DTS field, if one is defined to the file, is not updated. This means that a new DTS field defined as part of a file reorganization will not have a value calculated during the reorganization. Existing DTS fields are only added from TAPEI input, and they are not automatically updated by the DTS feature.
Usage
- If DTS is 0, your user thread does no date/time stamp processing on any file. To turn DTS processing off for a file, you must stop the file and turn off the FOPT X'10' bit. This suspends date/time stamp processing for this file for all users.
Currently, there is no feature that can suspend date/time processing for some files for some users.
- DTS is not supported under Parallel Query Option. If you attempt a remote open of a data/time stamp file (FOPT X'10' included), the following message is issued:
M204.1977: %F MAY NOT BE ACCESSED REMOTELY