Adding a date-time stamp field: Difference between revisions
Line 36: | Line 36: | ||
<b></b>*** 2 M204.0630: FILE OPEN COMMAND REJECTED | <b></b>*** 2 M204.0630: FILE OPEN COMMAND REJECTED | ||
</p> | </p> | ||
<p>If you do not set the [[DTSFN parameter|DTSFN]] system parameter, files with [[FOPT parameter|FOPT]]=X'10' cannot be opened. An OPEN command will not be processed and the following message is issued:</p> | <p>If you do not set the [[DTSFN parameter|DTSFN]] system parameter, files with [[FOPT parameter|FOPT]]=X'10' cannot be opened. An [[OPEN FILE command|OPEN]] command will not be processed and the following message is issued:</p> | ||
<p class="code">M204.2729: DATE/TIME STAMP FILE, BUT DTSFN UNSPECIFIED IN RUN | <p class="code">M204.2729: DATE/TIME STAMP FILE, BUT DTSFN UNSPECIFIED IN RUN | ||
</p> | </p> |
Revision as of 11:23, 5 June 2013
You can add a date-time stamp field to your files to keep track of when records in the file were last modified. The date-time stamp feature lets you put a date-time stamp (DTS) on each record that was updated in a transaction. You can then use the data in the date-time stamp field in an end-user written application to find and process all the rows of data that were changed.
An application that processes these records can track the date-time stamp field values that have been processed to date, or it may take another action, including updating the date-time stamp field.
After it is installed, the date-time stamp feature works only in files created in V7R1.0 or later. Under V6R1.0, DTS enabled files can be opened, and DTS fields read like any other, but no automatic updates to DTS fields will take place.
Note: There is no support in PQO/204 for the date/time stamp feature.
Overview of the date-time stamp feature
The date-time stamp (DTS) feature in Model 204 can track when records are modified.
Except for DELETE RECORD(S) processing, all other updates are captured, including those made by BATCH204 and ONLINE jobs. From V7R4.0 onwards, updates performed by IFAM applications are also captured.
The default date-time stamp format uses the operating system timestamp value. If your site prefers a different field value or a different data format, consult your Rocket Model 204 installation guide in order to customize the date-time stamp field name and to activate the date-time stamp feature.
Also of note:
- The DTS feature is implemented on a file-by-file basis.
- Precision and accuracy of the date-time stamp is to the millisecond when you use the date-time stamp feature as delivered. Rocket Software recommends that the date-time stamp field be defined as ORDERED CHARACTER to support ordered index FIND processing. (The length of this field value is 17 bytes.)
- While it should not be updated directly, you can read and display the date-time stamp as you can any other field. User Language and IFAM may both be used to find and display date-time stamp field data
- The date-time stamp field is updated at the beginning of commit processing when a new record is stored or an existing record is updated: changes, inserts, or deletes to fields or fieldgroups.
- You can exclude a user thread from date-time stamp field maintenance by resetting the DTS parameter to 0.
.
Extracting date-time stamp field data
Since the date-time stamp field is a normal Model 204 field, all methods of extraction may be used.
Date-time stamp field in User Language
The date-time stamp field may be:
- Read and printed either as a field name reference or through a $function.
- Searched in normal FIND statements.
- Assigned to %variables or other fields.
- Printed as supported for all Model 204 fields, including a PAI statement.
Date-time stamp field and OPEN processing
If the specified date-time stamp field name is not defined in a date-time stamp file, an OPEN command is rejected. If the date-time stamp field name is DATE.TIMESTAMP, for example, the following messages are issued:
> OPEN DTSFILE *** 1 M204.1265: NO SUCH FIELD NAME. FIELD = DATE.TIMESTAMP *** M204.2730: DATE/TIME STAMP FILE, BUT DTSFN NOT DEFINED IN FILE *** M204.0608: FILE CLOSED: DTSFILE *** 2 M204.0630: FILE OPEN COMMAND REJECTED
If you do not set the DTSFN system parameter, files with FOPT=X'10' cannot be opened. An OPEN command will not be processed and the following message is issued:
M204.2729: DATE/TIME STAMP FILE, BUT DTSFN UNSPECIFIED IN RUN
If you have reset DTS to 0, you must open DTS enabled files with file manager privileges. Otherwise, the open is rejected.
Date-time stamp considerations
Backup and recovery
If any errors occur during processing, the transaction is backed out.
Backup and recovery activity synchronize the date-time stamp with the data changes made. Date-time stamp field updates are part of your updating transaction and follow the normal Model 204 rules for BACKOUT, COMMIT, DUMP, RESTORE, ROLL BACK, and ROLL FORWARD.
File load utilities
FLOD and FASTLOAD do not update the date-time stamp values. However, you can manually update date-time stamp values as you might update another field name value pair.
Procedures with more than one request
If there are two requests in one procedure, for example, and neither COMMIT nor CLOSE is called between the two, then both requests are one transaction.
The following procedure has two requests.
BEGIN STORE a record in a DTS file END BEGIN PAI the record END
DTS updates are not displayed by the PAI output, since the transaction does not complete until the end of the procedure.
If there is no COMMIT in the first request or if the file is not closed after the first request, then the date-time stamp field is not updated.
If the same User Language requests are executed as separate procedures, the date-time stamp field is updated.
Suspending date-time stamp updates
There are two ways to suspend date=time stamp updates:
Suspending updates for all files on one thread's updates
A user with system manager privileges can exclude date-time stamp files from DTS processing, suspending DTS updates for that user's thread. The user's thread does no date-time stamp processing on any file.
To suspend DTS updates, reset the DTS parameter to 0. When DTS=0, the user can update any field, including the date-time stamp field, without automatically updating the date-time stamp field.
To reset the DTS parameter, the user must have system manager privileges. The user must also have file manager privileges for any DTS-enabled files opened, either before or after DTS is reset to 0.
Note: Automatic date-time stamp field updates are still performed for updates made to the files by other user threads with DTS set to 1.
Suspending all updates for a file
To disable all date-time stamp processing for a specific file, turn off the FOPT parameter X'10' bit on the command line or using the File Management Subsystem facility. Turning off this bit disables date-time stamp updates made by all users of that file.
For more information on the DTS and FOPT parameters, see the Rocket Model 204 Parameter and Command Reference.