Revision as of 09:37, 14 October 2014

Number of seconds before CPQZACTN

Summary

Default value
999,999, unless CPQZACTN is explicitly set.
Parameter type
System
Where set
On User 0's parameter line or reset by system manager
Related products
All
Introduced
Model 204 V5.1

Description

The CPQZSECS parameter establishes an extended quiesce timer. An extended quiesce begins after a successful checkpoint taken by a system following a CHECKPOINT SET EXTENDED QUIESCE command; it typically ends with a CHECKPOINT END EXTENDED QUIESCE command.

The CPQZSECS timer starts at the beginning of the extended quiesce. When the timer expires, the extended quiesce system takes the action specified in CPQZACTN.

The CPQZSECS parameter can be set to values 5 to 99999.