CPQZSECS parameter: Difference between revisions
Jump to navigation
Jump to search
Line 11: | Line 11: | ||
<dd>All | <dd>All | ||
<dt>Introduced | <dt>Introduced | ||
<dd><var class="product">Model 204 | <dd><var class="product">Model 204 V5.1</var> | ||
</dl> | </dl> | ||
Revision as of 09:37, 14 October 2014
Number of seconds before CPQZACTN
Summary
- Default value
- 999,999, unless CPQZACTN is explicitly set.
- Parameter type
- System
- Where set
- On User 0's parameter line or reset by system manager
- Related products
- All
- Introduced
- Model 204 V5.1
Description
The CPQZSECS parameter establishes an extended quiesce timer. An extended quiesce begins after a successful checkpoint taken by a system following a CHECKPOINT SET EXTENDED QUIESCE command; it typically ends with a CHECKPOINT END EXTENDED QUIESCE command.
The CPQZSECS timer starts at the beginning of the extended quiesce. When the timer expires, the extended quiesce system takes the action specified in CPQZACTN.
The CPQZSECS parameter can be set to values 5 to 99999.