M204.1065
M204.1065 token was not previously defined
An ALLOCATE, USE name, USE PRINTER, USE PUNCH, or DEFINE (except for DEFINE FIELD) command failed due to one of the following reasons:
- You issued ALLOCATE tokenwith no other parameters, but token was not previously defined using a DEFINE DATASET command.
- You issued ALLOCATE name LIKE token, but token was not previously defined using a DEFINE DATASET or ALLOCATE command. token is displayed in the message.
- You issued a DEFINE DATASET/PRINTER/PROCESS/PUNCH/STREAM name LIKE tokencommand, but token was not previously defined with the DEFINE command. token is substituted in the message.
- You issued USE token, USE PRINTER token, orUSE PUNCH token, but token does not exist.
Response: Verify that name or token are correctly defined, and retry the command.
Message attributes:
| RETCODEO=0 | Sets online return code | 
|---|---|
| RETCODEB=4 | Sets batch (single user) return code | 
| CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter | 
| AUDITER | Writes the message with line type ER to the audit trail | 
| COUNT | Increments the error count (ERCNT) parameter |