M204.1065
Jump to navigation
Jump to search
M204.1065 token was not previously defined
An ALLOCATE, USE name, USE PRINTER, USE PUNCH, or DEFINE (except for DEFINE FIELD) command failed due to one of the following reasons:
- You issued
ALLOCATE token
with no other parameters, but token was not previously defined using a DEFINE DATASET command. - You issued
ALLOCATE name LIKE token
, but token was not previously defined using a DEFINE DATASET or ALLOCATE command. token is displayed in the message. - You issued a
DEFINE DATASET/PRINTER/PROCESS/PUNCH/STREAM name LIKE token
command, but token was not previously defined with the DEFINE command. token is substituted in the message. - You issued
USE token, USE PRINTER token
, orUSE PUNCH token
, but token does not exist.
Response: Verify that name or token are correctly defined, and retry the command.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |