M204.1065
M204.1065 token was not previously defined
An ALLOCATE, USE name, USE PRINTER, USE PUNCH, or DEFINE (except for DEFINE FIELD) command failed due to one of the following reasons:
- You issued
ALLOCATE name
with no other parameters, but name has not been previously defined using a DEFINE DATASET command. - You issued
ALLOCATE name LIKE name2
, but name2 was not previously defined using a DEFINE DATASET or ALLOCATE command. In this case, name2 is displayed in the message. - You issued a
DEFINE DATASET/PRINTER/PROCESS/PUNCH/STREAM name LIKE name2
command, but name2 was not previously defined with the DEFINE command. In this case, name2 is substituted in the message. - You issued
USE name, USE PRINTER name
, orUSE PUNCH name
, but name does not exist.
Response: Verify that name or name2 are correctly defined, and retry the command.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |