M204.1307
M204.1307 token logon rejected - token2 (reason code: hexValue)
The MODEL 204 3270 terminal handler has rejected a logon request from a 3270 terminal for the reason stated. The following reason codes are defined:
- There are no control blocks available for new logons. Increase the number of IODEV 7 terminal definitions. The reason text is: NOT ENOUGH 3270 TERMINALS.
- The terminal has been defined with a non-3270 transmission services profile. The LU type must be 2. The reason text is: LU TYPE NOT = 2.
- The terminal has been defined to require definite responses to messages it sends inbound to the host. The transmission services profile must be 3.
The reason text is: TS PROFILE NOT = 3. - There has been an error on this terminal. This is a retryable error. The reason text is: LOSTERM SET FOR THIS TERMINAL.
- The terminal definition is in use. This error should not occur. The reason text is: TERMINAL ALREADY IN USE.
System manager response: Contact your SNA Communications Server (VTAM) systems programmer to correct the SNA Communications Server definition.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |
OPR | Writes the message to the (operator) console |
SAVE | Saves the message in the VIEW ERRORS table |