EOJPW parameter

From m204wiki
Revision as of 19:11, 3 June 2016 by JAL (talk | contribs) (→‎Description: minor formatting)
Jump to navigation Jump to search

EOJ password

Summary

Default value
None
Parameter type
System
Where set
CCAIN
Related products
None
Introduced
Model 204 V6.1

Description

The EOJPW value is used as a "password" that the system manager must enter to confirm that they are ending the correct run.

If the EOJPW parameter (4 bytes maximum) is set in CCAIN, then after the system manager confirms that Online termination is desired, they are prompted for the EOJPW value.

So, if EOJPW is set, and the EOJ command returns:

M204.1076: DO YOU REALLY WANT TO END THE RUN FOR {location | jobname}?

And the system manager responds with Y, the M204.1076 message is followed with:

M204.0347: Password

and the system manager must enter the value of EOJPW.

If EOJPW is not set, no password prompt is issued.

See the EOJ command description for more information about the M204.1706 confirmation message.