M204.0169
M204.0169 Bug .. reapplying RF entry type entryType, subtype subType from updunit updateUnitNum to file fileName recNum
A Model 204 system error occurred. Model 204 encountered an error while attempting to reapply an update during ROLL FORWARD processing. When available, a record number is included in this message.
System manager response: Contact Technical Support. Please have the following documentation available:
- Complete text of the error message
- Audit trail from both this run and the previous run
- Snap
If follow-up diagnosis is necessary, Technical Support requires copies of the following items:
- CCARF or CCAGEN data set
- RESTART data set, if this is RESTART recovery
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
SNAP | Generates a CCASNAP for the run |
DUMP | Generates a SYSUDUMP for the entire Model 204 region |