M204.0169  Bug .. reapplying RF entry type entryType​,​ subtype subType from updunit updateUnitNum to file fileName recNum

A Model 204 system error occurred. Model 204 encountered an error while attempting to reapply an update during ROLL FORWARD processing. When available, a record number is included in this message.

System manager response: Contact Technical Support. Please have the following documentation available:

  • Complete text of the error message
  • Audit trail from both this run and the previous run
  • Snap

If follow-up diagnosis is necessary, Technical Support requires copies of the following items:

  • CCARF or CCAGEN data set
  • RESTART data set, if this is RESTART recovery

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITADWrites the message with line type AD to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
SNAPGenerates a CCASNAP for the run
DUMPGenerates a SYSUDUMP for the entire Model 204 region