M204.1750  CCASYS missing field token

A field that Model 204 expects to be defined in the CCASYS file is not defined. This might occur during conversion to a new version of Model 204 when CCASYS from a previous version is used. It could also be the result of an error in the Dictionary/204 installation process.

System manager response: If Dictionary/204 has been recently installed, check to see if any error conditions were reported during that process. If converting to a new version of Model 204, check the Release Notes for any special procedures required for the processing of old CCASYS files.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter