M204.1750 CCASYS missing field token
A field that Model 204 expects to be defined in the CCASYS file is not defined. This might occur during conversion to a new version of Model 204 when CCASYS from a previous version is used. It could also be the result of an error in the Dictionary/204 installation process.
System manager response: If Dictionary/204 has been recently installed, check to see if any error conditions were reported during that process. If converting to a new version of Model 204, check the Release Notes for any special procedures required for the processing of old CCASYS files.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |