M204.2255  Value specified in LDC violates BINARY data type validation​,​ field ignored: token ​=​ token2

The fieldname=value constant specified in a LoaD Constant (LDC) Fastload statement is in violation of BINARY data type validation. The file to be loaded by the FLOD job has NUMERIC VALIDATION specified in the FILEMODL parameter; the specific field to be loaded is BINARY.

This error message occurs during FLOD compilation, and it prevents Fastload from loading any data to the file.

Response: Correct the LDC instruction by supplying a valid BINARY constant. Re-run the FLOD job.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter

Back to list of messages