CPQZACTN parameter
Summary
- Default value
- X'80', unless the CPQZSECS parameter is explicitly set.
- Parameter type
- System
- Where set
- On User 0's parameter line or reset by system manager
- Related products
- All
- Introduced
- Model 204 V6.1 or earlier
Description
If an extended quiesce is in progress, one of the following actions will take place when the CPQZSECS time limit expires. The action depends on the setting of CPQZACTN. The settings are mutually exclusive.
Setting | Meaning |
---|---|
X'10' | EOJ - terminate the run |
X'20' | OPERATOR - prompts the Operator to provide what action to take: EOJ, ENDEQ, or CONTINUE |
X'40' | ENDEQ - end extended quiesce state, release all updating users |
X'80' | CONTINUE - the extended quiesce should continue for the length of CPQZSECS seconds |
If the extended quiesce is ended before the CPQZSECS time limit expires, the CPQZACTN setting is ignored.