MSIR.0749 (error) during (action), no Sirius debug info

From m204wiki
Revision as of 15:01, 9 November 2010 by 198.242.244.47 (talk) (Created page with "A severe error occurred while performing the indicated action with objects. The two possible errors are "Object $list full" or "CCATEMP full". ;p An "Object $list full" error sug...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

A severe error occurred while performing the indicated action with objects. The two possible errors are "Object $list full" or "CCATEMP full". ;p An "Object $list full" error suggests the use of too many objects in an application. Since the size limit of the object $list is approximately 3-gigabytes, this suggests either a loop in the application, or an "extreme" application that is pushing the limits of the Janus SOAP technology. In the former case, correct the application. In the latter case, contact Sirius Software for ideas on how such an application might be better structured.

An "CCATEMP full" error suggests either a loop in the application, or an insufficient CCATEMP allocation for the Online. In the former case, correct the application. In the latter, allocate more CCATEMP to the Online. 
To get more debugging info such as the procedure and line number in which the error occurred, rerun the request with the DEBUGUL user parameter set or the 1 bit set in the SIRFACT system parameter. The latter can only be done if SirFact is installed.