EOJPW parameter

From m204wiki
Revision as of 19:51, 6 January 2014 by JDamon (talk | contribs) (Created page with "{{Template:EOJPW parameter subtitle}} ==Summary== <dl> <dt>Default value <dd>None <dt>Parameter type <dd>System <dt>Where set <dd>CCAIN <dt>Related products <dd>None <dt>Intro...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

EOJ password

Summary

Default value
None
Parameter type
System
Where set
CCAIN
Related products
None
Introduced
Model 204 V6.1

Description

If the CCAIN parameter, LOCATION, is supplied, then a non-user zero EOJ command will return 'DO YOU REALLY WANT TO END THE RUN FOR location ?'. This will enable the user to determine that they are ending the correct run. Likewise, a new CCAIN parameter, EOJPW, may also be supplied. If so, after the above message is affirmed, a new prompt for 'PASSWORD?' will occur. If an incorrect password is entered, as supplied by EOJPW, the run will NOT end and the user is returned to command level. If neither LOCATION nor EOJPW is entered, no changes will be observed.