EOJPW parameter
EOJ password
Summary
- Default value
- None
- Parameter type
- System
- Where set
- CCAIN
- Related products
- None
- Introduced
- Model 204 V6.1
Description
If the EOJPW parameter (4 bytes max) is set in CCAIN, then a non-user zero EOJ command will return
M204.1076: DO YOU REALLY WANT TO END THE RUN FOR {location | jobname} ?
- If the LOCATION parameter is also set in CCAIN, then location will be set to that value in the M204.1076 message.
- If CUSTOM=37 is set, then jobname in the M204.1076 message will be replaced by the value of JOBNM, a view only parameter.
- If "Y" is the response to the M204.1076 message, that message will be followed with
- M204.0347: Password
If EOJPW is not set, no password prompt will be issued. However, the M204.1076 message will be issued in one of the following forms.
-
1) If CUSTOM=37 is set:
- M204.1076: Do you really want to end the run for jobname?
-
2) If CUSTOM=37 is not set and LOCATION is set:
- M204.1076: Do you really want to end the run for location?
-
3) If CUSTOM=37 is not set, and LOCATION is not set:
- M204.1076: Do you really want to end the run?
This feature will enable the user to confirm that they are ending the correct run.