New and updated messages in Model 204 version 7.7

From m204wiki
Jump to navigation Jump to search

******THIS IS A DRAFT DOCUMENT.******

Back to 7.7 release notes

M204 messages

M204.0064: NDBSERVS cannot be less than NSERVS+2, reset to NSERVS+2

If DEBUGOPT=x'02' (server swapping debugging facility) is set, the number of debug servers (NDBSERVS) must be greater than or equal to the number of servers (NSERVS+2).

System manager response: Set NDBSERVS to NSERVS+2 or greater.

Return codes: E 0 4 AUDITAD


M204.0478: RACF message display limit reached; not all messages are displayed

RACF login messages for the current session have exceeded the number of bytes available for their display. Further messages will not be displayed.

Response: No response is needed. This message is for information only.

Return codes: I 0 0 AUDITMS


M204.0543: Warning: procedure can't COPY into itself: procname

As of release 7.7, this message specifies the COPY action and indicates the procedure name.

The running procedure, procname, contains a COPY PROC command that has attempted to copy a procedure into itself.

Response: Specify a different output procedure or previous request with the COPY PROC command.

Return codes: E 0 4 AUDITMS


M204.1414: ERROR: SORT RECORD > 16MEG

As of release 7.7, this error condition results in an error message and not a snap.

The user has exceeded the 16M sort record limit.

System manager response: Correct and retry.

Return codes: C 0 4 CANCEL AUDITER


M204.1610: Only 4095 images allowed for a single block

As of release 7.7, the number of allowed images has been increased to 4095.

More than 4095 IMAGE statements appear before the first END IMAGE. All of the images describe the same block of data. Model 204 allows a maximum of 4095 images of a single data block.

Response: Reduce the number of images of this block to 4095 or less. Note that items can redefine part of an image using the AT clause without creating a separate image definition. If the images describe separate blocks of data, insert END IMAGE statements between the images. Retry the request.

Return codes: C 0 4 ECHO AUDITER


M204.2316: TCPIP ERROR: category, PROCESS=process_name, REMOTEID=remote_id, SEITUH=data_header

As of release 7.7, this message no longer issues a snap.

Unexpected data has been received on this connection requiring the connection to be closed. process_name identifies the name of the process opened at the time of error. remote_id identifies the remote Internet address. SEITUH is the data header (for Rocket Software internal use).

Response: Contact the System Manager.

System manager response: Obtain the CCAAUDIT file and contact Technical Support.

Return codes: C 0 20 AUDITER NOTERM


M204.2956: File filename is in-memory file

File filename is defined as an in-memory file, which has no zHPF capabilities.

Return codes: I 0 0 AUDITAD


M204.2957: Error errno opening stream streamname for Janus Web port portname

This message indicates why the open failed for the TCPLOG stream streamname for the Janus Web port portname, where errno indicates the problem:

Number Meaning
1 Operation failed
2 Stream id is not available
3 Nonexistent stream or unauthorized access
4 Permanent I/O error
5 End-of-data or record not found
6 Data length greater than buffer length
7 Data validation error
8 Stream not ring or concatenated
9 All ring members full, cannot switch
10 Offload process failed
11 Terminal attention
12 File full condition
13 Reread required for OS-concatenation
14 GCORE problem for arbitration buffers
15 Parallel stream members differ

Return codes: I 0 0 AUDITAD NOTERM


M204.2958: APSYPAGE is obsolete as of 7.6. Rocket recommends using RESPAGE and/or TEMPPAGE as the alternative

As of version 7.7, setting APSYPAGE to non-zero results in an error and prevents the Online from coming up.

System manager response: Set APSYPAGE to 0 and use an alternative; see APSYPAGE parameter for details.

Return codes: C 0 4 AUDITER


M204.2960: Initialized interface (ESM) (version)

This message is issued during Model 204 startup when a Model 204 interface to an External Security Manager (RACF, ACF2, or Top Secret) has been successfully initialized. The message identifies the relevant ESM and its version.

The AUTHCTL VIEW command may be used by a System Manager to get more information about the current security environment.