MSIR.0159 SYBMSG(20159,15,1) '(Statement)' statement invalid after EXEC statement.

From m204wiki
Revision as of 20:39, 7 July 2016 by JAL (talk | contribs) (link repair)
Jump to navigation Jump to search

This message indicates that statement was received after the EXEC statement in a stream being handled by EXEC2RPC processing on a Janus Open Server port. This is indicative of an error in the client code. Turning on language/RPC debugging with a JANUS TRACE 3 command and re-running the request will send the data being sent by the client to the Model 204 audit trail.


Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter
NOTERMDoes not display the message on the user's terminal

Back to list of messages