M204.1307 token logon rejected - token2 (reason code: hexValue)
The Model 204 3270 terminal handler has rejected a logon request from a 3270 terminal for the reason stated. The following reason codes are defined:
- There are no control blocks available for new logons. Increase the number of IODEV 7 terminal definitions. The reason text is: 
NOT ENOUGH 3270 TERMINALS. - The terminal has been defined with a non-3270 transmission services profile. The LU type must be 2.  The reason text is: 
LU TYPE NOT=2. - The terminal has been defined to require definite responses to messages it sends inbound to the host. The transmission services profile must be 3. 
The reason text is:TS PROFILE NOT=3. - There has been an error on this terminal. This is a retryable error. The reason text is: 
LOSTERM SET FOR THIS TERMINAL. - The terminal definition is in use. This error should not occur. The reason text is: 
TERMINAL ALREADY IN USE. 
System manager response: Contact your SNA Communications Server (VTAM) systems programmer to correct the SNA Communications Server definition.
Message attributes:
| RETCODEO=0 | Sets online return code | 
|---|---|
| RETCODEB=4 | Sets batch (single user) return code | 
| CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter | 
| AUDITAD | Writes the message with line type AD to the audit trail | 
| NOCOUNT | Does not increment the error count (ERCNT) parameter | 
| NOTERM | Does not display the message on the user's terminal | 
| OPR | Writes the message to the (operator) console | 
| SAVE | Saves the message in the VIEW ERRORS table |