B24EXCWT parameter

From m204wiki
Jump to navigation Jump to search

BATCH204 wait time(ms) between M204.0583 msgs

Summary

Default value
240000
Parameter type
System
Where set
On User 0's parameter line
Related products
All
Introduced
Model 204 V7.1

Description

The BATCH204 wait time increment, in milliseconds, between each reissue of this message:

M204.0583: WAITING FOR EXCLUSIVE ACCESS TO FILE data set name

A batch Model 204 run is attempting to establish an exclusive enqueue on a Model 204 file, but another job already has an exclusive or share enqueue outstanding for the file. Model 204 retries the enqueue and waits for the file to become available. If an exclusive enqueue is not available after B24EXCWT milliseconds, the message is reissued, and Model 204 again waits for the file to become available.