Line 38: Line 38:
+1 if either the SYSOPT 1 bit or 2 bit is set
+1 if either the SYSOPT 1 bit or 2 bit is set
  +2 if both the SYSOPT 1 and 2 bits are set</li>
  +2 if both the SYSOPT 1 and 2 bits are set</li>
<li>
If the value of the <var class="product">Model&nbsp;204</var> KOMMOPT parameter is X '00', the default, extra control blocks are needed. Add 2944 bytes to the FIXSIZE calculation.</li>
<li>
<li>
If any SQL threads (IODEV 19) are specified in the CCAIN, add 6328 bytes for C language work areas to the FIXSIZE calculation. </li>
If any SQL threads (IODEV 19) are specified in the CCAIN, add 6328 bytes for C language work areas to the FIXSIZE calculation. </li>

Revision as of 22:13, 24 March 2014

Fixed server size requirement

Summary

Default value
None
Parameter type
Utable
Where set
View-only
Related products
All
Introduced
Model 204 V6.1 or earlier

Description

The size of the user's server tables that are fixed by initialization

For non-SQL processing, FIXSIZE is determined according to the following calculation:

FIXSIZE = 2536 + ((LAUDPROC + 9) * 4)dwr + (LIBUFF + 4)dwr + (LOBUFF + 5)dwr + (LOUTPB)dwr + ((NGROUP + 12) * (NRMTFILE + NFILES + 1)) + (NRMTFILE + 1)dwr + (3 * (NORQS + 1))dwr

where:

  • dwr, "double word rounded," means round to the next multiple of eight, unless it already is a multiple of eight.
  • The following adjustments might apply:
    • NRMTFILE is zero except for PQO users.
    • Add to the NFILES term (since its CCAIN value gets increased automatically by Model 204): +1 if either the SYSOPT 1 bit or 2 bit is set +2 if both the SYSOPT 1 and 2 bits are set
    • If any SQL threads (IODEV 19) are specified in the CCAIN, add 6328 bytes for C language work areas to the FIXSIZE calculation.

Fixed server tables as well as variable server tables, those that can be modified during the Model 204 run, are discussed in Chapter 2 of the Model 204 System Manager's Guide.